       This is a publication of Fluke Industrial B.V.,
		DIAGNOSTIC TOOLS DIVISION
		 Almelo, The Netherlands
	       1995,1997 Fluke Corporation


   Product      :  SW33W for Windows
                   FlukeView CombiScope Software

   Version      :  2.0
   Date         :  November 19, 1997

   Contents:    1. "Duplicate File Found" message during SETUP
                2. Known problems with FlukeView

   ____________________________________________________________

   1. "DUPLICATE FILE FOUND" MESSAGE DURING SETUP

   The setup program of FlukeView, copies the files PDQCOMM2.VBX,
   CMDIALOG.VBX, COMMDLG.DLL, THREED.VBX, VBCTL3D.VBX 
   and VBRUN300.DLL to the SYSTEM directory of WINDOWS.

   The following message will be given when one of these files
   is originally present in the \WINDOWS\SYSTEM directory:

      "File <filename> is already present. If FlukeView cannot
       be started, remove the file <filename>"

   When this message is shown, FlukeView does not replace the
   original file in your WINDOWS\SYSTEM directory. If FlukeView
   cannot be started, the original file is not compatible with
   the <filename> version supplied with FlukeView.
   To start FlukeView, rename the file <filename> for backup
   reasons and run the FlukeView Setup program again.
 
   ____________________________________________________________

   2. KNOWN PROBLEMS WITH FLUKEVIEW

   Please note the following problems you may encounter when 
   using FlukeView for Windows:

   a. When a mouse is connected to a COM port with the same
      interrupt level as the COM port to which the CombiScope is
      connected, the connection to the CombiScope may fail.
      This can occur when COM1 and COM3 (or COM2 and COM4) are
      used, for example.
      To solve this problem, connect the mouse or the CombiScope
      to another COM port or change the interrupt level of a COM
      port (refer to the documentation of the PC or the serial
      interface card).

   b. During communication with the CombiScope, when you move the
      mouse over the border of a window or over the stop button,
      the following error may occur:

         "Communication error: Overrun error detected."

                                Tip

      Select the standard VGA display from the Windows Setup
      to overcome this problem.

   c. When the mouse is positioned above a button on the toolbar,
      the statusbar displays a text that describes the button. If
      the mouse is quickly moved away, the text may not disappear.

   d. When resizing a window results in large text characters, 
      disable the Windows setting "True Type Fonts Only".

      For Windows 3.1, start the Control Panel program and select
      Fonts, True Type..., and disable "Show Only True Type Fonts 
      in Applications".

      For Windows 95, select My Computer, Control Panel, Fonts,
      View - Options, True Type, and disable "Show only True Type
      fonts in the programs on my computer".

      For Windows NT, select My Computer, Control Panel, Fonts,
      View - Options, True Type Fonts, and disable "Show only True
      Type fonts in the programs on my computer".

   e. When the CombiScope is in the Single Trigger mode and no
      waveform has been acquired yet, the error message "Timeout"
      is given. 

   ____________________________________________________________

   End of the README.TXT file.